Basic Info.
Certification
CCC, RoHS, ISO, CE
Power Source
Electric Power
Temperature
Ordinary Temperature
Transport Package
Paper Carton
Specification
150mm x 100mm x60mm
Product Description
Fisher Fieldvue DVC6200 Digital Valve Controller positioner
- Area Classification: Explosion Proof, Intrinsically Safe, FISCO, Type N, Flame Proof, Non-incendive for FM
- Certifications: FM, ATEX, IECEx, CUTR, Lloyd's Register, Peso KGS, INMETRO, NEPSI, TIIS, Natural Gas Certified, Single Seal Device
- Communication Protocol: 4-20 mA HART
- Data Interface: Wired
- Diagnostics: Yes
- Input Signal: Electric
- Max Outlet Pressure: 145 psig
- Mounting Type: Integral Mounted
- Operating Temperature: Standard Temperature, High Temperature
- Process Control: Flow, Pressure, Temperature, Level
- Position Control: Throttling Control, On/Off
- Power Source: Local
- Supply Media: Air, Natural Gas, Nitrogen
- Linkage-Less Feedback System: Eliminates wearing on parts
Base Instrument Model* |
DVC6200H | Digital Valve Controller with 4-20 mA input and HART 5 communication |
DVC6200F | Digital Valve Controller with FOUNDATION fieldbus digital communication |
DVC6200P | Digital Valve Controller with PROFIBUS PA digital communication |
1. Hazardous Area Approvals* |
1A | Explosion proof, Intrinsically Safe, Non-incendive; Class/Division & Zone |
1B | FM - Explosion proof, Intrinsically Safe, Non-incendive; Class/Division & Zone |
1C | ATEX - Intrinsically Safe, Ex ia (Gas & Dust) |
1D | ATEX - Flameproof, Ex d |
1E | ATEX - Non-incendive, Type n |
1F | IECEx - Flameproof, Intrinsically Safety, Non-incendive (Gas & Dust) |
1G | INMETRO (Brazil) - Flameproof, Intrinsically Safe, Type n |
1H | KGS (South Korea) - Flameproof, Intrinsically Safe |
1I | NEPSI (China) - Flameproof, Intrinsically Safe, Type n |
1J | CUTR EAC (Russia, Belarus, Kazakhstan, Armenia) |
1K | PESO (India) - Flameproof, Intrinsically Safe, Type n |
1L | TIIS (Japan) - Flameproof (not applicable for DVC6200P) |
2. Housing Material* |
2A | Aluminum |
2B | Stainless Steel, includes fluorosilicone elastomers. Housing B only |
3. Housing Style* |
3A | Housing B (Standard design) |
3B | Housing A (Integrated aluminum housing for use with Fisher GX valves only) |
4. Foundation Fieldbus Function Blocks* |
4A | Not Applicable, DVC6200H or DVC6200P selected |
4B | DVC6200F with Fieldbus Logic (on/off control): DO, DI (4) function blocks |
4C | DVC6200F with Fieldbus Control (modulating control): AO function block ONLY |
4D | DVC6200F with Standard Control (modulating control): ALL available function blocks |
5. Pneumatic Action* |
5A | Single-Acting DIRECT operation (RELAY C) |
5B | Single-Acting REVERSE operation (RELAY B) |
5C | DOUBLE-Acting operation (RELAY A) |
6. Position Feedback I/O Options for DVC6200H* |
6A | Not Applicable, DVC6200F or DVC6200P selected |
6B | DVC6200H without I/O options |
6C | DVC6200H with 4-20 mA Position Feedback Transmitter enabled (Limit Switch disabled) |
6D | DVC6200H with Single Limit Switch enabled (Position Feedback Transmitter disabled) |
7. Gauges* |
7A | None - Outlets will be plugged |
7B | None - Tire valve connections required |
7C | Supply & Output gauges, dual scaled 0-60 psig, 0-4 bar |
7D | Supply & Output gauges, dual scaled 0-60 psig, 0-0.4 Mpa |
7E | Supply & Output gauges, dual scaled 0-60 psig, 0-4 kgm2 |
7F | Supply & Output gauges, dual scaled 0-160 psig, 0-11 bar |
7G | Supply & Output gauges, dual scaled 0-160 psig, 0-1.1 Mpa |
7H | Supply & Output gauges, dual scaled 0-160 psig, 0-11 kgm2 |
8. Threaded Connections* |
8A | 1/2 NPT conduit & 1/4 NPT pneumatic |
8B | 1/2 NPT conduit with M20 x 1.5 ISO brass adaptor & 1/4 NPT pneumatic |
8C | 1/2 NPT conduit with M20 x 1.5 ISO SST adaptor & 1/4 NPT pneumatic |
8D | M20 conduit with 1/4 NPT pneumatic(1) |
9. Diagnostic Level* |
AC | Auto Calibration for DVC6200H: Set-up via Device Communicator (not applicable for DVC6200F or DVC6200P |
HCFD | HART Communication/Fieldbus Diagnostics: Basic digital communication with alerts; applicable to all protocols. |
AD | Advanced Diagnostics: HCFD features plus off-line diagnostics when used with ValveLink software (Not applicable for DVC6200P) |
PD | Performance Diagnostics: AD features plus on-line in-service diagnostics when used with ValveLink software (Not applicable for DVC6200P) |
PS | Partial Stroke Testing for DVC6200F devices ONLY (Not Applicable for DVC6200H or DVC6200P. See DVC6200 SIS for PST with HART) |
Address:
Zhenxing District, Taoyuan Street 66, Dandong, Liaoning, China
Business Type:
Trading Company
Business Range:
Bags, Cases & Boxes, Construction & Decoration, Electrical & Electronics, Industrial Equipment & Components, Instruments & Meters, Manufacturing & Processing Machinery, Office Supplies, Packaging & Printing, Service
Management System Certification:
ISO 9001
Company Introduction:
Dandong Dedan Trade Co., Ltd is the subsidiary company for Dandong Premier Instrument Co., Ltd and takes the responsibility of export work. Dandong Premier Instrument Co., Ltd located in Dandong of Liaoning province, established since 1990, professional produce each type of level, flow transmitter and other X ray instruments. Include displacer level transmitters, radar level transmitters, magnetic level indicator, glass plate gauge, orifice, venturi etc, and other instruments include X ray diffractometer, X ray orientation instrument, etc Also we are flexible and offer more service for customers. We always would like to be the purchase office for the customers in China. Our goal is offering the best service for the customers around the world.
Meanwhile we offer the export service for the manufacturers near our factories and establish one export group for our local famous brand. We carry on ISO9001 management for all of the export work, monitor the production and test the quality of the goods, further issue the Qualify Certificate. For years development, we won the trust from our customers and gained good reputation over the world We will be always doing our best for the aboard friends.