Interface Measurement Displacer Level Transmitters Foxboro 244LD
Original foxboro 244LD transmitter import from France
WN flange from 150# till 2500#
316LSS material
Main technical parameter
Power supply: 12~30V DC;
Output signal: 4~20 mA DC
increase; Negative direction - the increase of level, interface, or density make output decrease.)
Measuring range: 300mm-2500mm (can also over range)
Nominal pressure: ≤42.0Mpa
Nominal diameter: DN40 or as customers' request
Ambient temperature: -40ºC to +80ºC (when ≤-30ºC, no LCD display)
Operating temperature: -70ºC to +400ºC
Measuring accuracy: 0.2%
Influence from power supply: When the voltage of the power supply varies between min. and max. ,the output change is within <±0.2%. of the full scale.
LCD display: Output current signal,process variable,process temperature,percentage range,rotation angle of torque tube.
Medium density difference: ≥0.08g/cm³
Material of torque tube: Standard configuration Inconel 600,or Monel, HasetlloyC-276
Wetted material: 304,316L or as customers' request
Flange standard: HG/T20592-2009,HG/T20615-2009 or as customers' request
Power entry: Two NPT 1/2 (female thread) or as customers' request
Explosion-proof: Explosion isolation ExdCT6, Intrinsically safe ExiaCT6
Protection grade: IP66
Alarm jumper: For the self-diagnosis to the inaccuracy failure of the process variables (for example, the electronic module failure). Configure the process variables of high and low alarms.
Operation principle
DLC series smart displacer level (interface) transmitter consists of imported original DLC3000 series smart level controller and measuring chamber, measuring mechanism, displacer and torque tube, etc. The liquid level changing triggers the change of the buoyancy of displacer, then it will be transferred into the torque tube unit. This makes the torque tube and core axle rotate synchronously.
At the same time, the magnetic steel parts that fixed at the core axle of the torque tube turn rotary displacement. The Hall-effect sensor senses the magnetic field change and converts the magnetic signals into current signals. DLC3000 series smart level controller measures process variables with a controller and relative electronic circuit, supplies current output to drive LCD and support HART communication. Controller receives the electric signals that have been temperature-compensated and linearised. Meanwhile, compensates the liquid density change caused by the change of the process temperature, then supplies 4~20mA current output signals. LCD can indicate analog output, process variables, process temperature (if RTD is installed), degrees of the torque tube rotation and percent range of variable, etc.
Model |
|
|
|
Code |
|
|
|
|
Code meaning |
244LD- |
|
|
|
|
|
|
|
|
244LD Smart displacer transmitter |
|
1 |
|
|
|
|
|
|
|
Level measurement |
|
2 |
|
|
|
|
|
|
|
Interface measurement |
|
3 |
|
|
|
|
|
|
|
Density measurement |
|
|
A |
|
|
|
|
|
|
Top-side mounted |
|
|
B |
|
|
|
|
|
|
Top-bottom mounted |
|
|
C |
|
|
|
|
|
|
Side-side mounted |
|
|
D |
|
|
|
|
|
|
Bottom-side mounted |
|
|
E |
|
|
|
|
|
|
Top mounted |
|
|
F |
|
|
|
|
|
|
Side mounted |
|
|
S |
|
|
|
|
|
|
Top-bottom S style mounted |
|
|
|
2 |
|
|
|
|
|
Nominal pressure ≤PN1.6MPa, 2.0Mpa (Class 150) |
|
|
|
3 |
|
|
|
|
|
Nominal pressure: PN2.5MPa |
|
|
|
4 |
|
|
|
|
|
Nominal pressure: PN4.0MPa |
|
|
|
5 |
|
|
|
|
|
Nominal pressure: PN5.0MPa (Class 300) |
|
|
|
6 |
|
|
|
|
|
Nominal pressure: PN6.3Mpa |
|
|
|
10 |
|
|
|
|
|
Nominal pressure ≤PN10MPa |
|
|
|
11 |
|
|
|
|
|
Nominal pressure ≤PN11MPa (Class 600) |
|
|
|
15 |
|
|
|
|
|
Nominal pressure ≤PN15MPa (Class 900) |
|
|
|
16 |
|
|
|
|
|
Nominal pressure ≤PN16MPa (Class 900) |
|
|
|
25 |
|
|
|
|
|
Nominal pressure ≤PN25MPa (Class 900) |
|
|
|
26 |
|
|
|
|
|
Nominal pressure ≤PN26MPa (Class 1500) |
|
|
|
42 |
|
|
|
|
|
Nominal pressure ≤PN42.0MPa (Class 2500) |
|
|
|
|
/ |
|
|
|
|
Intrinsically safe |
|
|
|
|
|
i |
|
|
|
Explosion protection: intrinsically safe |
|
|
|
|
|
d |
|
|
|
Explosion protection: explosion isolation |
|
|
|
|
|
|
T |
|
|
Chamber material : carbon steel |
|
|
|
|
|
|
H |
|
|
Chamber material: 304 (others as actual fill in) |
|
|
|
|
|
|
R |
|
|
Chamber material: 316L (others as actual fill in) |
|
|
|
|
|
|
F |
|
|
Chamber material: Stainless with PTFE coated |
|
|
|
|
|
|
X |
|
|
Chamber material: Other material |
|
|
|
|
|
|
|
L |
|
Medium temperature: -70ºC≤T<-30ºC |
|
|
|
|
|
|
|
D |
|
Medium temperature:-30ºC≤T<+100ºC |
|
|
|
|
|
|
|
G |
|
Medium temperature: +100ºC≤T≤+400ºC |
|
|
|
|
|
|
|
|
/ |
|
|
Range According to actual fill in, unit is mm. |
Additional code |
F |
Chamber with heating, flange connection DN15, PN2.5 RF |
Z |
Chamber with heating, thread joint R1/2 |
|
W |
Left mounted transmitter mounted transmitter) |
(without |
"W" |
is |
right |
Example : UTZ-2C3/iTD/800F: smart displacer, measuring interface, side-side mounted, nominal pressure is PN6.3MPa or PN5.0MPa intrinsically safe, chamber material is carbon steel, medium temperature-30ºC≤T <
+100ºC, measuring range is 800mm, chamber with heating, flange connection with heating tracing.