• Premier Precision Milk Oil Coriolis Mass Flowmeter
  • Premier Precision Milk Oil Coriolis Mass Flowmeter
  • Premier Precision Milk Oil Coriolis Mass Flowmeter
  • Premier Precision Milk Oil Coriolis Mass Flowmeter
  • Premier Precision Milk Oil Coriolis Mass Flowmeter
  • Premier Precision Milk Oil Coriolis Mass Flowmeter

Premier Precision Milk Oil Coriolis Mass Flowmeter

Accuracy: ±0.6-1%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil
Size: DN25-1000
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Premier Precision Milk Oil Coriolis Mass Flowmeter pictures & photos
Premier Precision Milk Oil Coriolis Mass Flowmeter
US $500 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Trading Company

Basic Info.

Sensor
Plug-in
Application
Energy Metering
Type
Coriolis Mass Flow Meter
Measuring Media
Liquid
Measuring Principle
Mechanics
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Material
Carbon Steel or Stainless
Transport Package
Wooden Case
Specification
customized
Trademark
dd
Origin
Dalian

Product Description

Premier Precision Milk Oil Coriolis Mass Flowmeter
1 MTCMF Mass Flow Meter Overview




Coriolis mass flow meter (MTCMF) is a new type flow meter which is designed according to Micro Motion and Coriolis principle.This kind of new flow meter can measure the fluid directly in a sealed pipeline. It consists of two sections: Sensor and Signal Transmitter.

1.1 Main Features

  • Unchallengeable MTCMF performance on liquid mass flow, volume flow, and density measurement
  • Unique design delivers unparalleled measurement sensitivity and stability
  • Guarantees consistent, reliable performance over the widest flow range
  • Designed to minimize process, mounting, and environmental effect

1.2 Application

The MTCMF mass flow meter can be used in the following fields to meet the requirements of ingredient, mixing processes and commercial measurement.
  • Chemical: containing chemical reaction system
  • Petroleum:  moisture content analysis
  • Lipids: including vegetable oils, animal fats and other oils
  • Pharmaceutical
  • Painting
  • Paper making
  • Textile printing and dyeing
  • Fuel: crude oil, heavy oil, coal slurry, lubricant and other fuels.
  • Food: gas dissolving beverage, health drink and other liquid.
  • Transportation: pipeline liquid measurement.
  • Low temperature fluid, like liquid oxygen and liquid nitrogen, the low temperature up to -200ºC
  • High temperature fluid, the maximum temperature up to 300ºC
  • High pressure fluid, like slurry flow measurement for oil drilling cementing
Model Nominal Size (mm) Flow rate (t/hr)
MTCMF-003 3 0~0.14~0.18
MTCMF-006 6 0~0.6~0.72
MTCMF-008 8 0~0.96~1.2
MTCMF-010 10 0~1.6~2.1
MTCMF-015 15 0~3.6~4.5
MTCMF-020 20 0~6~7.2
MTCMF-025 25 0~9.6~12
MTCMF-032 32 0~18~21
MTCMF-040 40 0~30~36
MTCMF-050 50 0~48~60
MTCMF-080 80 0~150~180
MTCMF-100 100 0~240~280
MTCMF-150 150 0~480~600
  1. ±0.1~0.5%
  1. ±0.1~0.25%
  2. measurement range: 0.5~2g/cm3, Accuracy: ±0.002 g/cm3
  3. temperature: -50~+200ºC, (Min.-200ºC, Max.:300ºC)
  4. temperature: -40~+60ºC  or  -20~+60ºC
  1. measuring tube material: SS316L; The housing material: SS304
  1. pressure: 4.0MPa, Max.: 35MPa
  2. Exd (ia)C T6Gb
Premier Precision Milk Oil Coriolis Mass Flowmeter
Premier Precision Milk Oil Coriolis Mass Flowmeter



MTCMF Mass Flow Meter Overview

Coriolis mass flow meter (MTCMF) is a new type flow meter which is designed according to Micro Motion and Coriolis principle.This kind of new flow meter can measure the fluid directly in a sealed pipeline. It consists of two sections: Sensor and Signal Transmitter.

1.1 Main Features

  • Unchallengeable MTCMF performance on liquid mass flow, volume flow, and density measurement
  • Unique design delivers unparalleled measurement sensitivity and stability
  • Guarantees consistent, reliable performance over the widest flow range
  • Designed to minimize process, mounting, and environmental effect

1.2 Application

The MTCMF mass flow meter can be used in the following fields to meet the requirements of ingredient, mixing processes and commercial measurement.
  • Chemical: containing chemical reaction system
  • Petroleum:  moisture content analysis
  • Lipids: including vegetable oils, animal fats and other oils
  • Pharmaceutical
  • Painting
  • Paper making
  • Textile printing and dyeing
  • Fuel: crude oil, heavy oil, coal slurry, lubricant and other fuels.
  • Food: gas dissolving beverage, health drink and other liquid.
  • Transportation: pipeline liquid measurement.
  • Low temperature fluid, like liquid oxygen and liquid nitrogen, the low temperature up to -200ºC
  • High temperature fluid, the maximum temperature up to 300ºC
  • High pressure fluid, like slurry flow measurement for oil drilling cementing

1.3 Working Principle

If a pipe is rotated around a point (P) while liquid is flowing through it (toward or away from the center of rotation), that fluid will generate an inertial force, with reference to 
A particle (δm) travels to the right at a constant velocity (v) inside a tube. The tube is rotating around a fixed point (P) at angular velocity (w), in this case, this particle will get two acceleration components:
Normal acceleration (centripetal acceleration), its value is equal to w2r, its direction is toward the point P
Tangential acceleration a1 (Coriolis acceleration), its value is equal to 2wv, its direction is perpendicular to v

For special rotational pipe, its frequency is constant, ΔFc only depends on δqm. Therefore, directly or indirectly measuring the Coriolis force can be measured mass flow. This is how Coriolis mass flow meter works.

The actual flow sensor can't achieve rotational movement, replace by pipeline vibration. The principle is shown in Figure1.2,Figure1.3,Figure1.4. Both ends of a bend pipe are fixed, and the vibration force is applied to the pipe in an middle of the two fixed points (according to the resonance frequency of pipeline), taking the fixed point as axis, making pipeline vibrate at its natural frequency (w). When no fluid flows through the pipeline, the pipeline is only affected by vibration force, the vibration direction of two half-section of pipeline is the same, no phase difference. When fluid flows, by the influence of fluid medium dot Coriolis force Fc inside the pipeline (In the two half-section of pipeline, Coriolis F1 and F2 are equal in magnitude and opposite in direction Figure 1.2), two half-section of pipeline occur twist in the opposite direction to generate phase difference which is proportional to mass flow. The design of sensor is converting the measurement of Coriolis force to the measurement of phase difference for both sides of the vibrating tube. This is the working principle of Coriolis mass flow meter.

 

2.2 Technical Parameters

  1. and Measuring Range
Specification DN (mm) Flow range(kg/h) Zero Stability, kg/h
 
Rated Pressure (MPa) NW
(kg)
GW
(kg)
0.2% 0.15% 0.1%
MTCMF-003 3 0~96~120 0.018 0.012 0.012 40 8 19
MTCMF-006 6 0~540~660 0.099 0.066 0.066 20 12 22
MTCMF-008 8 0~960~1200 0.18 0.12 0.12 20 12 23
MTCMF-010 10 0~1500~1800 0.27 0.18 0.18 20 11 24
MTCMF-015 15 0~3000~4200 0.63 0.42 0.42 20 12 25
MTCMF-020 20 0~6000~7800 1.17 0.78 0.78 16 20 34
MTCMF-025 25 0~10200~13500 2.025 1.35 1.35 16 21 35
MTCMF-032 32 0~18 000~24 000 3.6 2.4 2.4 16 27 45
MTCMF-040 40 0~30 000~36 000 5.4 3.6 3.6 12 35 55
MTCMF-050 50 0~48 000~60 000 9 6 6 12 40 60
MTCMF-080 80 0~120 000~160 000 24 16 16 8 90 150
MTCMF-100 100 0~222 000~270 000 40.5 27 27 8 170 245
MTCMF-150 150 0~480 000~600 000 90 60 60 6 255 350
  
Model A B C D E NW(only sensor)
mm mm mm mm mm kg
MTCMF-010 200 350 350 58 225 7.2
MTCMF-015 250 453 500 89 228 7.5
MTCMF-020 250 448 500 89 233 17
MTCMF-025 550 500 445 108 238 17.5
MTCMF-032 550 500 445 108 240 24
MTCMF-040 600 760 500 140 245 32
MTCMF-050 600 760 500 140 253 36
MTCMF-080 850 1050 780 220 315 87.5
MTCMF-100 1050 1085 840 295 358 165
MTCMF-150 1200 1200 950 320 340 252
MTCMF-200 1200 1193 1000 400 358 350
Premier Precision Milk Oil Coriolis Mass Flowmeter
 
Model A B C D E NW
mm mm mm mm mm kg
MTCMF-003 178 176 250 54 244 4.8
MTCMF-006 232 263 360 70.5 287 8.1
MTCMF-008 232 275 395 70.5 290 8.2
MTCMF-010 95 283 370 70.5 242 6.5
MTCMF-015 95 302 405 70.5 242 6.5
Note: A size will be changed with the different process connection.
3 Selection and Installation

3.1 Selection

The following conditions should be considered for flow meter selection.
Medium characteristics
  • Measurability
Coriolis mass flow meter is widely used for lots of fluid, but some conditions like slug flow, pulsating flow etc, where you want to install Coriolis mass flow meter, some appropriate support measures must be taken.
  • Corrosivity
Coriolis mass flow meter measuring tube material is SS316L, housing material SS304. If the standard material is not suitable for the medium, anticorrosion wetted material should be selected.
  • Operating temperature and pressure
Standard configuration: -50…+200ºC, 4.0MPa, please contact with manufacturer for special parameters.
  • Ambient condition
Standard ambient temperature is -20…+60ºC. The flow meter will fail to display if the ambient temperature exceeds the standard range. Please contact with manufacturer for special parameters.
  • Protection and Explosion
Transmitter ex-proof: flame type, Sensor ex-proof: intrinsic type
Transmitter and Sensor protection: IP67
Preferred measuring range 1/3~2/3 of standard flow range
Allowable pressure loss Pressure loss should be considered especially for reduced pipe.
Pressure loss reference table is shown as below

Pressure Loss Reference Table
Diameter Max standard flow Pressure loss Max extended flow Pressure loss
mm Kg/h Pa Kg/h Pa
3 96 100000 120 150000
6 540 100000 660 150000
8 960 100000 1200 150000
10 1500 100000 1800 150000
15 3000 100000 4200 150000
20 6000 100000 7800 150000
25 10200 100000 13500 150000
32 18000 80000 24000 150000
40 30000 75000 36000 100000
50 48000 65000 60000 100000
80 120000 60000 160000 100000
100 222000 65000 270000 100000
150 480000 60000 600000 90000
 Premier Precision Milk Oil Coriolis Mass Flowmeter

3.2.1 Basic Requirements on installation

  • Flow direction should be in accordance with MTCMF sensor flow arrow.
  • Properly supporting is required for preventing tubes vibrating.
  • If a strong pipeline vibration is inevitable, it is recommended to use a flexible tube to isolate the sensor from the pipe.
  • Flanges should be kept parallel and their center points should be located on the same axis to avoid subsidiary force generation.
  • Installation vertically, make the flow from the bottom up when measuring, meanwhile, the meter should not be installed on the top to prevent air getting trapped inside the tubes.
Premier Precision Milk Oil Coriolis Mass Flowmeter
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Premier Precision Milk Oil Coriolis Mass Flowmeter pictures & photos
Premier Precision Milk Oil Coriolis Mass Flowmeter
US $500 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Trading Company
Number of Employees
4
Year of Establishment
2018-06-22