Intelligent Buoyancy Transmitter with Torque Tube Foxboro 244LD buoyancy displacer level transmitter Wafer Body Material (Process wetted): 1.0460 (~A 105 Carbon Steel), application from - 10°C to 350°C .......................................... -K 1.4404 (316L) or 1.4435 if Pressure Rating codes H1 and H2 are selected, application from -60 °C to 400 °C ........................................ -S 1.4404 (316L) or 1.4435 if Pressure Rating codes H1 and H2 are selected, application from - 196 °C to 400 °C ...................................... -U 1.4404 (316L) or 1.4435 if Pressure Rating codes H1 and H2 are selected, application from -60 °C to 500 °C ........................................ -T 1.4541 (321), application from -60 °C to 400 °C ..................... -H 1.4462 (Duplex), application from - 10 °C to 280 °C ................ -N 2.4856 (Inconel 625), application from - 196 °C to 450°C ....... -R 2.4858 (Inconel 825), application from - 10 °C to 450°C (on request) ...........................................................................-I 2.4819 (Hastelloy C276), appl. from - 196 °C to 400°C -C Torque Tube Material (Process wetted): 1.4404 (316L) S Hastelloy C276 X 2.4816 (Inconel 600) I 2.4375 (Monel K500) M Wafer Body Flange Size (Nominal size): DN 70 (available with Wafer Body Material S, U, T, and Torque Tube Material S and X) 0 DN 80 1 DN 100 2 3 inch 3 4 inch 4
|
Wafer Body Pressure Rating & Contact Face PN40 (PN16 to PN40) B1/B1 acc. to DIN EN 1092-1 B1 PN250 (PN16 to PN250) B2/B2 acc. to DIN EN 1092-1 (a) ........ B2 PN250 (PN16 to PN250) D/C (Groove Face / Tongue Face acc. to DIN EN 1092-1) (a)(r) ....... DC PN250 (PN16 to PN250) D/D (Groove Face / Groove Face acc. to DIN EN 1092-1) (a) ........ DD PN250 (PN16 to PN250) F/F (Recess Face / Recess Face acc. to DIN EN 1092-1) (a) ........ FF PN250 (PN16 to PN250) F/E (Recess Face / Spigot Face acc. to DIN EN 1092-1 (a)(s) ...... FE PN250 (PN16 to PN250) L/L (Lens Face / Lens Face acc. to DIN 2696) (a) ........ L1 PN400 L/L Lense (Lens Face / Lens Face acc. to DIN 2696) (k)(n) ...... H1 PN500 L/L Lense (Lens Face / Lens Face acc. to IG-Norm High Pressure Version) ........................................... (i)(n) ....... H2 ANSI Class 150 RF/RF (Raised Face / Raised Face) ............................ (b) ........ R1 ANSI Class 900 (300/600/900) RF/RF (Raised Face / Raised Face) .... (b) ........ R2 ANSI Class 1500 RF/RF (Raised Face / Raised Face) .......................... (b) ........ R3 ANSI Class 150 SF/SF (Smooth Finish / Smooth Finish) ...................... (b) ........ S1 ANSI Class 900 (300/600/900) SF/SF (Smooth Finish/Smooth Finish) . (b) ........ S2 ANSI Class 1500 SF/SF (Smooth Finish / Smooth Finish) .................... (b) ........ S3 ANSI Class 150 RJF/RJF (b) .........J1 ANSI Class 900 (300/600/900) RJF/RJF (b) .........J2 ANSI Class 1500 RJF/RJF (b) .........J3 ANSI Class 300 to 1500, LF/LM (Large Female* / Large Male) (b) ........ LM ANSI Class 300 to 1500, LF/LF (Large Female / Large Female) (b) ........ LF ANSI Class 300 to 1500, LG/LT (Large Groove* / Large Tongue) (b) ........ LT ANSI Class 300 to 1500, LG/LG (Large Groove / Large Groove) (b) ........ LG ANSI Class 150, SG/ST (Small Groove* / Small Tongue) ..................... (b) ........ GT ANSI Class 300 to 1500, SG/ST (Small Groove / Small Tongue) .......... (b) ........ ST ANSI Class 150, SG/SG (Small Groove / Small Groove) ....................... (b) ........GG ANSI Class 300 to 1500, SG/SG (Small Groove / Small Groove) .......... (b) ........ SG Wafer Body Mounting Direction: (Amplifier to body) Right Hand mounted ....................................................................................................... R Right Hand mounted with heating jacket - - connecting flanges B1 / DN15, PN40 (DIN EN 1092-1) (m)(o)(z) ............... A - connecting flanges B1 / DN25, PN40 (DIN EN 1092-1) (m)(o)(z) ............... B - connecting flanges B2 / DN15, PN40 (DIN EN 1092-1) (m)(o)(z) ............... C - connecting flanges B2 / DN25, PN40 (DIN EN 1092-1) (m)(o)(z) ............... D - connecting flanges RF/SF, 1/2 inch, Class 300 (m)(o)(z) ............... E - connecting flanges RF/SF, 1 inch, Class 300 (m)(o)(z) ................F - connecting flanges RJF, 1/2 inch, Class 300 (m)(o)(z) ............... G - connecting flanges RJF, 1 inch, Class 300 (m)(o)(z) ............... H Left Hand mounted L
|
Version: Base VERSION - LEVELSTAR - (244LD) (f)(v) ......................N Cable Entry: M20x1.5 without cable gland M 1/2-14 NPT without cable gland N Communication: HART H FOUNDATION Fieldbus H1 (aa) .......................................... B Electrical Classification: ATEX intrinsic safe Zone 0, IIC T4 (HART) (d) ......................................... 0C4 ATEX intrinsic safe Zone 0, IIC T6 (HART or FOUNDATION Fieldbus) (d) ......................................... 0C6 ATEX intrinsic safe Zone 1, IIC T4 (HART) 1C4 ATEX intrinsic safe Zone 1, IIC T6 (HART or FOUNDATION Fieldbus) 1C6 ATEX intrinsic safe Zone 2, IIC T4(HART) 2C4 ATEX intrinsic safe Zone 2, IIC T6 (FOUNDATION Fieldbus) Zone 2, IIC T6 (HART) VERSION N, T, D (c) .......................................... 2C6 ATEX explosionproof Zone 0, IIC T6 (d) ......................................... D0C ATEX explosionproof Zone 1, IIC T6 D1C FM Explosionproof FDZ CSA Explosionproof CDZ EAC Intrinsically Safe Zone 0 - IIC T6 (z) .......................................... GA0 EAC Intrinsically Safe Zone 1 - IIC T6 .................................................................................................................. GA1 EAC Intrinsically Safe Zone 2 - IIC T6 .................................................................................................................. GA2 EAC Explosionproof Zone 0 - IIC T6 ..................................................................... (z) ..........................................GD0 EAC Explosionproof Zone 1 - IIC T6 ....................................................................................................................GD1 NEPSI Intrinsically Safe, Ex d ia IIB/IIC T4/T6 Ga/Gb or Ex d ia IIB/IIC T4/T6 Gb .............................................. NA6 NEPSI Explosionproof, Ex d IIB/IIC T4/T6 Gb ..................................................................................................... NDZ BRAZIL Intrinsically Safe, Ex d ib/ia IIC T6/T4 Gb/Ga ......................................................................................... BA6 BRAZIL Explosionproof, Ex d ib/ia IIC T6/T4 Gb ................................................................................................. BDZ For General Purpose Areas; without certification ................................................................................................. ZZZ
(continued on next page) |
OPTIONS: Housing Complete Stainless Steel .................................................................................................................................. -H External Push buttons for Maintenance........................................................................................ (y) .............................. -M Tag No. Labeling Stainless Steel Label Fixed with Wire ...........................................................................................................................-L Certificates EN 10204-2.1, Certificate of Compliance......................................................................................................................-1
PED 97/23/EC additional unit verification, acc. to module F/G .....................................................................................-4 EN 10204-2.2, Specific Test Report (Pressure Test)................................................................................................... -P Comply with NACE Standard MR-0175, not with Wafer Material K (carbon steel) and not with Torque Tube Material S (Stainless Steel); only with OPTION 3 ...........................................................-6 SIL 2 Certificate ........................................................................................................................ (q) .............................. -Q Material Test X-Ray or Isotope Test for Weldings ..............................................................................................................................-7 Dye Penetration Test ....................................................................................................................................................-8 PMI -Test ......................................................................................................................................................................-5 Subassemblies TRANSSTAR-housing with LEVELSTAR-electronic for selected code (244LD-*********-N)... (af) .............................. -N Torque Tube for selected code (244LD-*********-W)............................................................... (ab) .............................. -W Amplifier for selected code (244LD-*********-X) ...................................................................... (ac) .............................. -X Complete Sensor for selected code (244LD-*********-Y) ........................................................ (ad) .............................. -Y
(a) Available with Wafer Body Flange Size 1 or 2 (b) Available with Wafer Body Flange Size 3 or 4 (c) Pending (d) Not available with Wafer Body Pressure Rating & Contact Face codes L1, J1, J2, J3, H1, H2, and DD (e) Not available with Electrical Classification FDZ, CDZ, 0C6, D0C, D1C, GDZ, NDZ or Optional Features -H (f) Only with Communication H (HART) and electrical Classification 0C6, 1C6, D0C, D1C, 2C6 (i) Available with Wafer Body Flange Size 0 (k) Available with Wafer Body Flange Size 1 (m) Wafer Body Flange Size code 3 available only with Wafer Body Pressure Rating code R2, S2, J2 Wafer Body Flange Size code 4 available only with Wafer Body Pressure Rating code R1, S1, J1, GT, GG (n) Available with Wafer Body Material codes S, U, T, or Torque Tube Material codes S, C (o) Available with Wafer Body Material codes S, U, T (q) Only available with HART communication (r) D at top (s) F at top (v) Pending Electrical Classification FDZ, CDZ, GA6, GDZ, NA6, NDZ, BA6, BDZ (w) Version N, T, D with external Pushbuttons (y) Not with Options -H and Version B, S or C (z) Not with Pressure Rating H1 or H2 (aa) Levelstar with Electrical Classification D1C, D0C, 1C6, 0C6, 2C6, ZZZ (ab) Not with (Optional feature H, R, B, L, F, V, 9, K, A, G, 2, 4, Q, X, Y, or Z) (ac) Not with (Optional feature H, R, B, V, 9, K, A, G, 2, 3, 4, 6, Q, 7, 8, 5, W, Y, or Z) (ad) Not with (Optional feature H, R, B, L, F, V, 9, K, A, G, 2, Q, 7, 8, 5, W, X, or Z) (ae) PED required for Wafer Body Pressure Rating & Contact Face H1, H2 PED required for Wafer Body Material A, H, J, Q, R, T, C, N PED not available for Optional Feature X, Y, W (af) Not with (Optional features: M, R, B, V, 9, K, A, G, 2, 3, 4, 6, Q, 7, 8, 5, W, X, Y, or Z) |
Packing and delivery for Foxboro 244LD buoyancy displacer level transmitter