4-20mA Water Level Meter Foxboro 244ld Displacer Level Transmitter

Product Details
Customization: Available
Type: Level Measurement
Structure Design: Flange Type
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (14)
  • 4-20mA Water Level Meter Foxboro 244ld Displacer Level Transmitter
  • 4-20mA Water Level Meter Foxboro 244ld Displacer Level Transmitter
  • 4-20mA Water Level Meter Foxboro 244ld Displacer Level Transmitter
  • 4-20mA Water Level Meter Foxboro 244ld Displacer Level Transmitter
  • 4-20mA Water Level Meter Foxboro 244ld Displacer Level Transmitter
  • 4-20mA Water Level Meter Foxboro 244ld Displacer Level Transmitter
Find Similar Products

Basic Info.

Model NO.
244LD
Pressure Range
High Pressure
Display Type
LCD
Accuracy Grade
0.5G
IP Rating
IP68
Certification
CE
Customized
Customized
Name
Displacer Level Transmitter
Temperature
-196° to 400° C
Pressure
1 MPa to 40 MPa
Brand
Foxboro
Output
4-20mA
Model
244ld
Material
316lss
Price
USD2000
Original
France
Packing
Polywood Case
Transport Package
Wooden Case
Specification
customized
Trademark
foxboro
Origin
France
HS Code
9026100000
Production Capacity
500 PCS

Product Description

Foxboro 244LD Buoyancy Level Controller price 
4-20mA Water Level Meter Foxboro 244ld Displacer Level Transmitter
 4-20mA Water Level Meter Foxboro 244ld Displacer Level Transmitter
4-20mA Water Level Meter Foxboro 244ld Displacer Level Transmitter
4-20mA Water Level Meter Foxboro 244ld Displacer Level Transmitter

Main techni

4-20mA Water Level Meter Foxboro 244ld Displacer Level Transmitter
4-20mA Water Level Meter Foxboro 244ld Displacer Level Transmitter

 

4-20mA Water Level Meter Foxboro 244ld Displacer Level Transmitter
4-20mA Water Level Meter Foxboro 244ld Displacer Level Transmitter
4-20mA Water Level Meter Foxboro 244ld Displacer Level Transmitter
4-20mA Water Level Meter Foxboro 244ld Displacer Level Transmitter

 

4-20mA Water Level Meter Foxboro 244ld Displacer Level Transmitter
4-20mA Water Level Meter Foxboro 244ld Displacer Level Transmitter
The intelligent transmitter 244LD LevelStar is designed to perform continuous measurements for liquid
level, interface or density of liquids in the process of all industrial applications. The measurement is based on the
proven Archimedes buoyancy principle and thus extremely robust and durable. Measuring values can be
transferred analog and digital. Digital communication facilitates complete operation and configuration
via PC or control system. Despite extreme temperatures, high process pressure, and corrosive liquids, the 244LD
measures with consistent reliability and high precision. It is approved for installations in contact with explosive atmospheres. The 244LD combines our abundant experience with most advanced digital technology.

FEATURES
HART 7 Communication, 4 to 20 mA, or Foundation Fieldbus
Configuration via FDT-DTM
Multilingual full text graphic LCD
IR communication as a standard
Easy adaptation to the measuring point without
calibration at the workshop
Linear or customized characteristic
32 points linearization for volumetric measurement
Approved for SIL 2 applications (at HART)
Back documentation of measuring point
Continuous self diagnostics, Status, and diagnostic messages
Configurable safety value
Local display in %, mA, or physical units
Process temperature from -196 °C to +500 °C
Materials for use with aggressive media
Micro sinter metal sensor technology


parameter

Power supply: 12~30V DC;
Output signal: 4~20 mA DC
increase; Negative direction - the increase of level, interface, or density make output decrease.)
Measuring range: 300mm-2500mm (can also over range)
Nominal pressure: ≤42.0Mpa
Nominal diameter: DN40 or as customers' request
Ambient temperature: -40ºC to +80ºC (when ≤-30ºC, no LCD display)
Operating temperature: -70ºC to +400ºC
Measuring accuracy: 0.5%
Influence from power supply: When the voltage of the power supply varies between min. and max. ,the output change is within <±0.2%. of the full scale.
LCD display: Output current signal,process variable,process temperature,percentage range,rotation angle of torque tube.
Medium density difference: ≥0.08g/cm³
Material of torque tube: Standard configuration Inconel 600,or Monel, HasetlloyC-276
Wetted material: 304,316L or as customers' request
Flange standard: HG/T20592-2009,HG/T20615-2009 or as customers' request
Power entry: Two NPT 1/2 (female thread) or as customers' request
Explosion-proof: Explosion isolation ExdCT6, Intrinsically safe ExiaCT6
Protection grade: IP66
Alarm jumper: For the self-diagnosis to the inaccuracy failure of the process variables (for example, the electronic module failure). Configure the process variables of high and low alarms.

 

Operation principle

Intelligent Buoyancy Transmitter

with Torque Tube

Foxboro 244LD buoyancy displacer level transmitter

Wafer Body Material (Process wetted):

1.0460 (~A 105 Carbon Steel),

application from - 10°C to 350°C .......................................... -K

1.4404 (316L) or 1.4435 if Pressure Rating

codes H1 and H2 are selected,

application from -60 °C to 400 °C ........................................ -S

1.4404 (316L) or 1.4435 if Pressure Rating

codes H1 and H2 are selected,

application from - 196 °C to 400 °C ...................................... -U

1.4404 (316L) or 1.4435 if Pressure Rating

codes H1 and H2 are selected,

application from -60 °C to 500 °C ........................................ -T

1.4541 (321), application from -60 °C to 400 °C ..................... -H

1.4462 (Duplex), application from - 10 °C to 280 °C ................ -N

2.4856 (Inconel 625), application from - 196 °C to 450°C ....... -R

2.4858 (Inconel 825), application from - 10 °C to 450°C

(on request) ...........................................................................-I

2.4819 (Hastelloy C276), appl. from - 196 °C to 400°C   -C

Torque Tube Material (Process wetted):

1.4404 (316L)  S

Hastelloy C276  X

2.4816 (Inconel 600)  I

2.4375 (Monel K500)  M

Wafer Body Flange Size (Nominal size):

DN 70 (available with Wafer Body Material S, U, T,

and Torque Tube Material S and X)  0

DN  80  1

DN 100  2

3 inch  3

4 inch  4

 

Wafer Body Pressure Rating & Contact Face

PN40 (PN16 to PN40) B1/B1 acc. to DIN EN 1092-1  B1

PN250 (PN16 to PN250) B2/B2 acc. to DIN EN 1092-1  (a) ........ B2

PN250 (PN16 to PN250) D/C (Groove Face / Tongue Face

acc. to DIN EN 1092-1)  (a)(r) ....... DC

PN250 (PN16 to PN250) D/D (Groove Face / Groove Face

acc. to DIN EN 1092-1)  (a) ........ DD

PN250 (PN16 to PN250) F/F (Recess Face / Recess Face

acc. to DIN EN 1092-1)  (a) ........ FF

PN250 (PN16 to PN250) F/E (Recess Face / Spigot Face

acc. to DIN EN 1092-1  (a)(s) ...... FE

PN250 (PN16 to PN250) L/L (Lens Face / Lens Face

acc. to DIN 2696)  (a) ........ L1

PN400 L/L Lense (Lens Face / Lens Face

acc. to DIN 2696)  (k)(n) ...... H1

PN500 L/L Lense (Lens Face / Lens Face

acc. to IG-Norm High Pressure Version) ........................................... (i)(n) ....... H2

ANSI Class 150 RF/RF (Raised Face / Raised Face) ............................ (b) ........ R1

ANSI Class 900 (300/600/900) RF/RF (Raised Face / Raised Face) .... (b) ........ R2

ANSI Class 1500 RF/RF (Raised Face / Raised Face) .......................... (b) ........ R3

ANSI Class 150 SF/SF (Smooth Finish / Smooth Finish) ...................... (b) ........ S1

ANSI Class 900 (300/600/900) SF/SF (Smooth Finish/Smooth Finish) . (b) ........ S2

ANSI Class 1500 SF/SF (Smooth Finish / Smooth Finish) .................... (b) ........ S3

ANSI Class 150 RJF/RJF   (b) .........J1

ANSI Class 900 (300/600/900) RJF/RJF   (b) .........J2

ANSI Class 1500 RJF/RJF   (b) .........J3

ANSI Class 300 to 1500, LF/LM (Large Female* / Large Male)  (b) ........ LM

ANSI Class 300 to 1500, LF/LF (Large Female / Large Female)  (b) ........ LF

ANSI Class 300 to 1500, LG/LT (Large Groove* / Large Tongue)  (b) ........ LT

ANSI Class 300 to 1500, LG/LG (Large Groove / Large Groove)  (b) ........ LG

ANSI Class 150, SG/ST (Small Groove* / Small Tongue) ..................... (b) ........ GT

ANSI Class 300 to 1500, SG/ST (Small Groove / Small Tongue) .......... (b) ........ ST

ANSI Class 150, SG/SG (Small Groove / Small Groove) ....................... (b) ........GG

ANSI Class 300 to 1500, SG/SG (Small Groove / Small Groove) .......... (b) ........ SG

Wafer Body Mounting Direction: (Amplifier to body)

Right Hand mounted ....................................................................................................... R

Right Hand mounted with heating jacket -

- connecting flanges B1 / DN15, PN40 (DIN EN 1092-1)  (m)(o)(z) ............... A

- connecting flanges B1 / DN25, PN40 (DIN EN 1092-1)  (m)(o)(z) ............... B

- connecting flanges B2 / DN15, PN40 (DIN EN 1092-1)  (m)(o)(z) ............... C

- connecting flanges B2 / DN25, PN40 (DIN EN 1092-1)  (m)(o)(z) ............... D

- connecting flanges RF/SF, 1/2 inch, Class 300  (m)(o)(z) ............... E

- connecting flanges RF/SF, 1 inch, Class 300  (m)(o)(z) ................F

- connecting flanges RJF, 1/2 inch, Class 300  (m)(o)(z) ............... G

- connecting flanges RJF, 1 inch, Class 300  (m)(o)(z) ............... H

Left Hand mounted   L

 

 

Version:

Base VERSION - LEVELSTAR - (244LD)  (f)(v) ......................N  

Cable Entry:

M20x1.5 without cable gland   M

1/2-14 NPT without cable gland   N

Communication:

HART   H

FOUNDATION Fieldbus H1  (aa) .......................................... B

Electrical Classification:

ATEX intrinsic safe Zone 0, IIC T4 (HART)  (d) ......................................... 0C4

ATEX intrinsic safe Zone 0, IIC T6 (HART or FOUNDATION Fieldbus)  (d) ......................................... 0C6

ATEX intrinsic safe Zone 1, IIC T4 (HART)  1C4

ATEX intrinsic safe Zone 1, IIC T6 (HART or FOUNDATION Fieldbus)  1C6

ATEX intrinsic safe Zone 2, IIC T4(HART)  2C4

ATEX intrinsic safe Zone 2, IIC T6 (FOUNDATION Fieldbus)

Zone 2, IIC T6 (HART) VERSION N, T, D   (c) .......................................... 2C6

ATEX explosionproof Zone 0, IIC T6  (d) ......................................... D0C

ATEX explosionproof Zone 1, IIC T6  D1C

FM Explosionproof   FDZ

CSA Explosionproof   CDZ

EAC Intrinsically Safe Zone 0 - IIC T6  (z) .......................................... GA0

EAC Intrinsically Safe Zone 1 - IIC T6 .................................................................................................................. GA1

EAC Intrinsically Safe Zone 2 - IIC T6 .................................................................................................................. GA2

EAC Explosionproof Zone 0 - IIC T6 ..................................................................... (z) ..........................................GD0

EAC Explosionproof Zone 1 - IIC T6 ....................................................................................................................GD1

NEPSI Intrinsically Safe, Ex d ia IIB/IIC T4/T6 Ga/Gb or Ex d ia IIB/IIC T4/T6 Gb .............................................. NA6

NEPSI Explosionproof, Ex d IIB/IIC T4/T6 Gb ..................................................................................................... NDZ

BRAZIL Intrinsically Safe, Ex d ib/ia IIC T6/T4 Gb/Ga ......................................................................................... BA6

BRAZIL Explosionproof, Ex d ib/ia IIC T6/T4 Gb ................................................................................................. BDZ

For General Purpose Areas; without certification ................................................................................................. ZZZ

 

 

(continued on next page)

 

OPTIONS:

Housing Complete Stainless Steel .................................................................................................................................. -H

External Push buttons for Maintenance........................................................................................ (y) .............................. -M

Tag No. Labeling

Stainless Steel Label Fixed with Wire ...........................................................................................................................-L

Certificates

EN 10204-2.1, Certificate of Compliance......................................................................................................................-1

 

PED 97/23/EC additional unit verification, acc. to module F/G .....................................................................................-4

EN 10204-2.2, Specific Test Report (Pressure Test)................................................................................................... -P

Comply with NACE Standard MR-0175, not with Wafer Material K (carbon steel)

and not with Torque Tube Material S (Stainless Steel); only with OPTION 3 ...........................................................-6

SIL 2 Certificate ........................................................................................................................ (q) .............................. -Q

Material Test

X-Ray or Isotope Test for Weldings ..............................................................................................................................-7

Dye Penetration Test ....................................................................................................................................................-8

PMI -Test ......................................................................................................................................................................-5

Subassemblies

TRANSSTAR-housing with LEVELSTAR-electronic for selected code (244LD-*********-N)... (af) .............................. -N

Torque Tube for selected code (244LD-*********-W)............................................................... (ab) .............................. -W

Amplifier for selected code (244LD-*********-X) ...................................................................... (ac) .............................. -X

Complete Sensor for selected code (244LD-*********-Y) ........................................................ (ad) .............................. -Y

 

 

 

(a)   Available with Wafer Body Flange Size 1 or 2

(b)   Available with Wafer Body Flange Size 3 or 4

(c)    Pending

(d)   Not available with Wafer Body Pressure Rating & Contact Face codes L1, J1, J2, J3, H1, H2, and DD       (e)   Not available with Electrical Classification FDZ, CDZ, 0C6, D0C, D1C, GDZ, NDZ or Optional Features -H (f)    Only with Communication H (HART) and electrical Classification 0C6, 1C6, D0C, D1C, 2C6

(i)    Available with Wafer Body Flange Size 0 (k)   Available with Wafer Body Flange Size 1

(m)  Wafer Body Flange Size code 3 available only with Wafer Body Pressure Rating code R2, S2, J2

Wafer Body Flange Size code 4 available only with Wafer Body Pressure Rating code R1, S1, J1, GT, GG

(n)   Available with Wafer Body Material codes S, U, T, or Torque Tube Material codes S, C

(o)   Available with Wafer Body Material codes S, U, T

(q)   Only available with HART communication

(r)    D at top

(s)    F at top

(v)    Pending Electrical Classification FDZ, CDZ, GA6, GDZ, NA6, NDZ, BA6, BDZ

(w)   Version N, T, D with external Pushbuttons

(y)    Not with Options -H and Version B, S or C

(z)    Not with Pressure Rating H1 or H2

(aa) Levelstar with Electrical Classification D1C, D0C, 1C6, 0C6, 2C6, ZZZ

(ab) Not with (Optional feature H, R, B, L, F, V, 9, K, A, G, 2, 4, Q, X, Y, or Z)

(ac)  Not with (Optional feature H, R, B, V, 9, K, A, G, 2, 3, 4, 6, Q, 7, 8, 5, W, Y, or Z)

(ad) Not with (Optional feature H, R, B, L, F, V, 9, K, A, G, 2, Q, 7, 8, 5, W, X, or Z)

(ae) PED required for Wafer Body Pressure Rating & Contact Face H1, H2

PED required for Wafer Body Material A, H, J, Q, R, T, C, N

PED not available for Optional Feature X, Y, W

(af)  Not with (Optional features: M, R, B, V, 9, K, A, G, 2, 3, 4, 6, Q, 7, 8, 5, W, X, Y, or Z)

Packing and delivery for Foxboro 244LD buoyancy displacer level transmitter



 
Model       Code         Code meaning
UTZ-                 UTZ3100 Smart displacer transmitter
  1               Level measurement
  2               Interface measurement
  3               Density measurement
    A             Top-side mounted
    B             Top-bottom mounted
    C             Side-side mounted
    D             Bottom-side mounted
    E             Top mounted
    F             Side mounted
    S             Top-bottom S style mounted
      2           Nominal pressure ≤PN1.6MPa, 2.0Mpa (Class 150)
      3           Nominal pressure: PN2.5MPa
      4           Nominal pressure: PN4.0MPa
      5           Nominal pressure: PN5.0MPa (Class 300)
      6           Nominal pressure: PN6.3Mpa
      10           Nominal pressure ≤PN10MPa
      11           Nominal pressure ≤PN11MPa (Class 600)
      15           Nominal pressure ≤PN15MPa (Class 900)
      16           Nominal pressure ≤PN16MPa (Class 900)
      25           Nominal pressure ≤PN25MPa (Class 900)
      26           Nominal pressure ≤PN26MPa (Class 1500)
      42           Nominal pressure ≤PN42.0MPa (Class 2500)
        /         Intrinsically safe
          i       Explosion protection: intrinsically safe
          d       Explosion protection: explosion isolation
            T     Chamber material : carbon steel
            H     Chamber material: 304 (others as actual fill in)
            R     Chamber material: 316L (others as actual fill in)
            F     Chamber material: Stainless with PTFE coated
            X     Chamber material: Other material
              L   Medium temperature: -70ºC≤T<-30ºC
              D   Medium temperature:-30ºC≤T<+100ºC
              G   Medium temperature: +100ºC≤T≤+400ºC
                /  
  Range According to actual fill in, unit is mm.
Additional code F Chamber with heating, flange connection DN15, PN2.5 RF
Z Chamber with heating, thread joint R1/2
  W Left mounted transmitter
mounted transmitter)
(without "W" is right

Example : UTZ-2C3/iTD/800F: smart displacer, measuring interface, side-side mounted, nominal pressure is PN6.3MPa or PN5.0MPa intrinsically safe, chamber material is carbon steel, medium temperature-30ºC≤T <
+100ºC, measuring range is 800mm, chamber with heating, flange connection with heating tracing.









 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now