Energy Saving High Accuracy Flow Meter Venturi Tube Flow Meter

Product Details
Customization: Available
Accuracy: ±0.6-1%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (14)
Find Similar Products

Basic Info.

Size
DN25-1000
Sensor
Plug-in
Application
Energy Metering
Type
Variable Area Flow Meter
Measuring Media
Liquid
Measuring Principle
Mechanics
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Material
Carbon Steel or Stainless
Transport Package
Wooden Case
Specification
customized
Trademark
dd
Origin
Dalian

Product Description

LG Series Orifice Flow Measurement Throttle Device

Summary

Throttle device is the most historic and most extensively used flow measurement instrument. Its features are simple structure, easy installation, stable performance and high accuracy, etc merits. It can be used for flow measurement for liquid, steam and gas in modern industries. There are many kinds of throttle devices with a whole variety (being conformability with Standard GB/T2624-2006, Standard ISO5167-1-20031, Standard BS1042-1989 and Standard ASME) that are manufactured with advanced calculation methods and precise manufacturing means. They are applied extensively in petroleum, chemical, power, light industry, water supply field, gas transmission field etc.

LG Series Orifice Flow Measurement Throttle Device

Model composition and meaning

LG                ---                
                                                                           
                                                                           
                                            Pipe straight section code. See table 5
                                  Nominal pressure code. See table 4
                            Nominal diameter code. See table 3
                 Pressure measuring style code. See table 2
                                                                           
      Throttling element code. See table 1
                                                                         
Series number

Table 1 Throttling element code and meaning
Code Meaning Code Meaning
Y Standard orifice plate I Eccentric orifice plate
Q 1/4 circle orifice plate S Segmental orifice plate
X Small caliber orifice plate Z Raw cast contracted section (throat) Classic Venturi Tube
T Taper inlet orifice plate J Machined contracted section (throat) Classic Venturi Tube
M ISA1932 ejection nozzle H Iron plate welded contracted section (throat) Classic Venturi Tube
C Major diameter ejection nozzle W Venturi ejection nozzle
Table 2 Pressure measuring code and meaning
Code F H Z D T
Meaning Pressure measuring with flange Pressure measuring with angle joint ring chamber Pressure measuring with drilling hole Pressure measuring with two distanced holes Special pressure measuring
Table 3 Nominal diameter code and meaning
Code 01 016 02 026 03 04 05 06 08 10
DN mm 10 15 20 25 32 40 50 65 80 100
in   1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 4
 
Code 12 15 20 25 30 35 40 45 50 60
DN mm 125 150 200 250 300 350 400 450 500 600
in 5 6 8 10 12 14 16 18 20 24
Code 70 80 90 91            

LG Series Orifice Flow Measurement Throttle Device

 
1.0MPa Nominal diameter DN D LA LB LC
10 90 126 276 422
15 95 126 351 497
20 105 128 428 586
25 115 132 507 673
32 135 132 612 786
 
40 145 138 738 924
50 160 139 889 1075
65 180 141 1116 1314
80 195 146 1346 1552
100 215 146 1646 1860
 
125 245 159 2034 2280
150 280 159 2409 2655
200 335 163 3163 3417
For the above table, the length of the front straight section should be 10 times as long as the nominal diameter, the length of the rear straight section should be 5 times as long as the nominal diameter;
For the below table, the length of the front straight section should be 2000mm, the length of the rear straight section should be 1000mm.
250 390 166 3166 3432
300 440 162 3162 3428
350 500 164 3164 3430
400 565 164 3164 3430
450 615 176 3176 3462
 
500 670 190 3190 3508
600 780 212 3212 3578
700 895 210 3210 3576
800 1010 238 3238 3668
900 1110 242 3242 3680
1000 1220 242 3242 3680

LG Series Orifice Flow Measurement Throttle Device

Order requirements

  1. When purchasing throttle device, please fill in the specification table of throttle device (see below)
  Throttle Device Parameters Table Project NO.
Table NO.
Page.     Total.
Data Calculation
Operation conditions Fluid name   Throttle element type  
Operating temperature ºC   Pressure taking type  
Operating pressure  MPa   Select scale  
Flow Liquid       kg/h Max.   Select differential pressure  kPa  
Steam       kg/h Nor.   Min. flow limit  
Gas(standard)    Nm3/h Min.   Reynolds number          Re
(normal flow)  
 
Liquid           kg/m3   Area expansion correction
coefficient                   Fa
 
Steam           kg/m3   Expansion coefficient           ε  
Gas (standard)    kg/m3   Flow coefficient               α  
    Uncertainty                  %  
    Permanent pressure loss        Pa  
    Diameter ratio                βt  
    Hole diameter of throttle      mm
element or segmental height      
 
    1/4 circle radius or
eccentricity degree            mm
 
Operating density          kg/m3   Throttle device standard  
Dynamic viscosity         mPa.s      
Kinematic viscosity        mm2/s   Specification
Relative humidity (Φ)           
Compression coefficient (Z)   Model  
Isentropic exponent  (cp/cv)   Normal diameter (DN)  
Allowable pressure loss        Pa   Normal pressure (PN)           MPa  
Pipe Nominal diameter (DN)   Flange standard  
Pipe instrument number   Flange inner diameter         mm  
Outside diameter/inner diameter  mm   Structural length              mm  
Material   Pressure tape size             mm  
      Pressure tape location  
      material Throttle element  
      Flange  
      Bolt  
      Nut  
    Gasket  
Remark  

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier