Water System Control Fuel Oil Turbine Flow Meters

Accuracy: ±0.6-1%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil
Size: DN25-1000
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Water System Control Fuel Oil Turbine Flow Meters pictures & photos
Water System Control Fuel Oil Turbine Flow Meters
US $500 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Trading Company

Basic Info.

Sensor
Plug-in
Application
Energy Metering
Type
Electromagnetic Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, UL, RoHS, ISO
Material
Carbon Steel or Stainless
Transport Package
Wooden Case
Specification
customized
Trademark
dd
Origin
Dalian

Product Description

 

Liquid Turbine Flow Meter

LWG-N1 series              LWG-N2&A series       LWG-E series

                             




Operating Principle
Fluid entering the meter first passes through an inlet flow straightener that reduces its turbulent flow pattern. Fluid then passes through the turbine, causing the turbine to rotate at a speed proportional to fluid velocity. As each turbine blade passes through the magnetic field generated by the meter's magnetic pickup, an AC voltage pulse is generated. These pulses provide an output frequency that is proportional to volumetric flow.

Technical Data
-Output: Pulse/4-20mA
-Accuracy:±1.0 of Rate / ±0.5% of Rate
-Operating Temp.:-20.....+60ºC
-Fluid Temp.:-20.....+150ºC
-Body Material:SS304/SS316
-Rotor Material:2Cr13/CD4MCu
-Bearing Material:Turgsten Carbide

Description
The liquid turbine flow meter in the series LWG are specially designed for usage in water, diesel, gasoline and other fluid measurement and control systems.They operate according to the turbine principle, i.e. the speed of an impeller turning in the fluid flow is measured and converted into pulse or 4-20mA signals.




Flow Range
Diameter(mm) Standard Range(m³/h) Extended Rangem³/h)
4 0.04-0.25 0.04-0.4
6 0.1-0.6 0.06-0.6
10 0.2-1.2 0.15-1.5
15 0.6-6 0.4-8
20 0.8-8 0.45-9
25 1-10 0.5-10
32 1.5-15 0.8-15
40 2-20 1-20
50 4-40 2-40
65 7-70 4-70
80 10-100 5-100
100 20-200 10-200
125 25-250 13-250
150 30-300 15-300
200 80-800 40-800
 
Model Selection
Model Suffix Code
 
Description  
LWQ- 1 2 3 4 5 6 7 8 9 Liquid Turbine Flowmeter  
Diameter XXX                 Stand for diameter
004:DN4;006:DN6
100:DN100;200:DN200
 
Converter Type
 
N1               24V DC:Pulse output:No display  
N2               224V DC:Pulse output:No display:Ex  
A               24V DC:4-20mA output:No display:Ex  
E1               Battery power supply: No output:Ex:Digital display  
E2               24V DC:2-wire 4-20mA output:Ex:Digital display  
E3               24V DC:Pulse output:Ex:Digital display  
E4               24V DC:0-20mA output:Ex:Digital display  
E5               24V DC:3-wire 4-20mA/Pulse output:Ex:Digital display  
M               220Vac:4-20mA output:Ex:Digital display  
FE               FE:Fluidwell E series converter  
FF               FF:Fluidwell F series converter  
Notice               1)Modbus RS485 is optional for E2,E3,E4,E5 and M type  
2)Dual Power(24VDC+Battery) is optional for E2,E3,E4,E5,M  
Accuracy 10             ±1.0% of rate
05             ±0.5% of rate
02             ±0.2% of rate
Flow Range S           Standard Range
E           Extended Range
Body Material S4         SS304
S6         SS316
PL         Plastic(DN15-DN50)
Rotor Material Cr       2Cr13
CD       CD4MCu
Explosion Proof BT     Exd II BT6
NA     None
Connection THM   Male Thread; Available from DN4...DN50
THF   Female Thread; Available from DN4...DN50
WAF   Wafer connection
DXX   D16:DIN PN16 Flange:D25:DIN PN25 Flange..
AXX   A15:ANSI 150# Flange:A30:ANSI 300# Flange...
JXX    J10:JIS 10K Flange:J20:JIS 20K Flange..
Temperature T1 -20...+80ºC
T2 -20...+120ºC
T3 -20...+150ºC
         
 
Example:       1  2  3  4  5  6 7   8  9
         LWG 050 E5 10  S S4 Cr BT D16 T2
         1 050:DN50
         2 E5:3-wire 4-20mA/Pulse output:24V DC power supply
         3 10:1.0% of rate accuracy
         4 S:0.2-1.2m³/h
         5 S4:SS304 body material
         6 Cr:2Cr13 rotor
         7 BT:Exd II BT6
         8 D16:Flange DIN PN16
         9 T2:-20...120ºC
Dimensions
  1. Thread Connection
Diameter(mm) L(mm) Thread Criteria
4 270 G 1/2"
6 270 G 1/2"
10 390 G 1/2"
15 75 G 1"
20 80 G 1"
25 100 G 1-1/4"
32 140 G 2"
40 140 G 2"
50  150 G 2-1/2"
     


Notice: Other thread criteria is available on request.(Female/Male thread is optional for G,NPT,BSP)
  1. Flange Connection
Notice:The standard flange is DIN P16;but ANSI and JIS Flange are available on request.

 
Diameter  L  B Flange Diameter PCD Bolt Circle Diameter  Bolt Hole Quantity
 
(lnch) (mm) (mm) (mm) (mm)
1/2" 15 75 95 60 4
3/4" 20 80 105 70 4
1" 25 100 115 79 4
1-1/4" 32 140 140 89 4
1-1/2" 40 140 150 99 4
2" 50 150 165 121 4
2-1/2" 65 170 185 140 4
3" 80 200 200 152 4
4" 100 220 220 191 8
5" 125 250 250 216 8
6" 150 300 285 241 8
8" 200 360 340 298 8
Notice:Dimension above is for DIN PN16 Flange
Sanitary Liquid Turbine Flow Meter

Description
The sanitary liquid turbine flow meter is specifically designed for measurement of food liquids like milk, cream, juice of various fruits, pharma liquids etc. lt is available with compact or remote version of transmitter can be installed either horizontally or vertically with
a variety of optiona1 end-fittings to meet your requirements.

-DN4-DN100
-Viscosity from 1 to 10 cst
-Pressure resistant to 10 bar
-Communication: Modbus RS485/HART

Model Selection
Model Suffix Code
 
Description  
LMIS- 1 2 3 4 5 6 7 8 9 Sanitary Liquid Turbine Flow meter  
Diameter XXX                 Stand for diameter
004:DN4;
100:DN100;
 
Converter Type
 
N1               24V DC:Pulse output:No display  
N2               224V DC:Pulse output:No display:Ex  
A               24V DC:4-20mA output:No display:Ex  
E1               Battery power supply: No output:Ex:Digital display  
E2               24V DC:2-wire 4-20mA output:Ex:Digital display  
E3               24V DC:Pulse output:Ex:Digital display  
E4               24V DC:0-20mA output:Ex:Digital display  
E5               24V DC:3-wire 4-20mA/Pulse output:Ex:Digital display  
M               220Vac:4-20mA output:Ex:Digital display  
FE               FE:Fluidwell E series converter  
FF               FF:Fluidwell F series converter  
Notice               1)Modbus RS485 is optional for E2,E3,E4,E5 and M type  
2)Dual Power(24VDC+Battery) is optional for E2,E3,E4,E5,M  
Accuracy 10             ±1.0% of rate
05             ±0.5% of rate
02             ±0.2% of rate
Flow Range S           Standard Range
E           Extended Range
Body Material S4         SS304
S6         SS316
Rotor Material Cr       2Cr13
CD       CD4MCu
Explosion Proof BT     Exd II BT6
NA     None
Connection TRC   Tri-clamp for sanitaryConnection
Temperature T1 -20...+80ºC
T2 -20...+120ºC
T3 -20...+150ºC

Dimensions
 
Diameter  L  A B d D
(mm) (mm) (mm) (mm) (mm) (mm)
4 50 Φ46 Φ40.5 4 Φ50
6 50 Φ46 Φ40.5 6 Φ50
10 50 Φ46 Φ40.5 10 Φ50
15 100 Φ46 Φ40.5 15 Φ50
20 100 Φ46 Φ40.5 20 Φ50
25 100 Φ46 Φ40.5 25 Φ50
32 120 Φ46 Φ40.5 32 Φ50
40 140 Φ59 Φ53.5 40 Φ64
50 150 Φ73.5 Φ68 50 Φ78
65 170 Φ86 Φ80.5 65 Φ91
80 200 Φ100.5 Φ94 80 Φ106
100 220 Φ113 Φ106 100 Φ119
Mini Turbine Flow Meter
Description
Mini flow meter is based on turbine theory and designed for measuring micro-flow.This meter has extremely high accuracy especially under the condition of high temperature and high pressure.The Electronic pulse transmitter is also integrated in this min flow meter.It can maintain the 2% accuracy and 0.25       repeatability.Because of smart structure design,no debris can store in the working process and it's clear after work.
-55*40*47mm dimension
-About 300g
-NSF.CE authentication
-Coffee machine application


Technical Data
 
Items Diameter  Measuring Range K-Factor
 (mm) (L/mm)  (Ml/imp)
Measure Range 1.15 0.035-1.6 0.5
1.3 0.01-1.86 0.6
1.5 0.045-2.08 0.67
2 0.085-2.32 1.02
2.5 0.12-2.4 1.44
3.7 0.15-3.0 2.28
Pressure Maximum 20.2bar
Temperature -10ºC to 100ºC
Accuracy Level ±2%
Repetitive ±0.25%
Connection G 1/4 female thread  (ordered to meet need from customers)

Material
 Shell:Green Brass(lead-free brass)
Bearing:INO*18/8(1.4305) stainless steel
Turbine:PVDF(polyvinylidene fluoride)
Magnets:SrFeO ceramics




 
Model Suffix Code
 
 
LWQ- 1 2 3 4 5 6 7 8 Gas Turbine Flowmeter
Diameter XXX               Stand for diameter
0 20: DN20; 050: DN50
100: DN100; 400: DN400
Converter Type
 
N             24V DC; Pulse output; No display; Ex
A             24V DC; 4-20mA output; No display; Ex
 
E1             Battery power supply; No output; Ex; Digital display
E2             24V DC; 2- wire 4-20mA output; Ex; Digital display
E3             24V DC; Pulse output; Local display; Ex ; Digital display
E4             24V DC; 0-20mA output; Local display; Ex; Digital display
E5             24V DC; 3-wire 4-20mA/Pulse output; EX; Digital display
FE             Fluidwell E series converter ( Referto page 22)
FF             Fluidwell F series converter^ Refer to page 23)
D1             24V DC; 2-wire 4-20mA output; Digital display; Temperature & Pressure Compensation
D2             24V DC; 3-wire 4-20mA output; Digital display; Temperature & Pressure Compensation
D4             24V DC; 4-20mA output; Modbus RS485; Digital display Temperature&Pressure Compensation
Notice:             1)Modbus RS485 is optional for £2, E3, E4, E5, D1, D4
2)Battery Power(24VDC + Battery) is optional forE2, E3, E4, E5, D1, D2, D4
3)D4 converter only configures with cast steel body sensor
Accuracy 10           ±1.0% of rate
15           ±1.5% of rate
Flow Range S         Standard Range
E         Extended Range
Body Material S4       SS304
S6       SS316
CA       Cast Aluminum
CS       Cast Steel (Only for D4 type)
Rotor Material AB     ABS Plastic
AA     Aluminum Alloy
Explosion Proof BT   Exd II BT6
CT   ExiallCT4
NA   None
Connection   THM Male Thread; Available from DN4...DN50
  THF Female Thread; Available from DN4...DN50
  DXX DN16: DIN PN16 Flange; D25: DIN PN25 Flange...
  AXX A15: ANS1150# Flange; A30: ANSI 300# Flange...
  JXX J10: JIS 10K Flange; J20: JIS 20K Flange...


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Water System Control Fuel Oil Turbine Flow Meters pictures & photos
Water System Control Fuel Oil Turbine Flow Meters
US $500 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Trading Company
Number of Employees
4
Year of Establishment
2018-06-22